MAX KEYPAD Specifications
Values come from the MAX Keypad quick installation guide (Rev 2.8, April 2021) and page 32 of the 2025 MAX catalog.
| Required hardware | MAX Cell Hub; both work only with MAX gate operators |
|---|---|
| Power input | 12 V DC or AC; the guide wires a 12 V DC, 1 A transformer, polarity does not matter |
| Hub connection | RS-485, wired (+) to (+), (-) to (-), GND to GND |
| Hub capacity | Up to 16 access points per Cell Hub, keypads and Wiegand Converters combined |
| Access point switch | Rotary; 1 to 14 opens via the keypad relay; 0 via the Cell Hub only; 15 via the Cell Hub plus the keypad relay |
| User keycodes | 5 digits per user; Wiegand users entered as facility code plus Wiegand keycode |
| Time zones | Optional; 1 of 6 timer schedules, applied to keypad and Wiegand keycodes |
| Force open keycode | Up to 5 digits, one per gate site; hold the 0 key to jog the gate open, overriding the operator’s UL sensors |
| Greeting message | Up to 32 characters |
| Event log | Keypad keycode entries, Wiegand scans, app and guest pass OPEN commands, all programming changes |
| Housing | Tamper-resistant zinc die-cast front door; vandal-proof key lock; backlit, vandal-proof keys |
| Display and signals | Sunlight-readable LCD with contrast adjustment; speakers; HELP button; side LEDs for gooseneck visibility at night; light sensor for solar power management |
The guide shows two layouts: a pedestrian door, where the keypad relay drives a solenoid lock and an exit button feeds the RTE port, and an entry gate, where a Wiegand receiver or transponder wires to D0 and D1 and the gate opens through the Cell Hub. On a Riverside or Corona property with several entrances, number access points across the whole access control system before wiring.